Data center trunk cable

MTP Trunk Cable: Factory-Terminated Fiber Optic Trunks, 8F to 864F

MTP and MPO trunk cable from 8F to 864F, factory terminated and tested, in OS2 single-mode or OM3 and OM4 multimode with Type A, B or C polarity. Sourced build-to-order from tier 1 manufacturers and delivered in 6 to 8 weeks, with 2 to 3 week expedited air freight available.

MPO Trunk Cable on Reel with Pulling Eye (illustrative render) Illustrative render

Fiber optic trunks, built to order

  • 8F to 864F
  • Type A, B or C
  • OS2, OM3, OM4
  • Factory tested

Need a different count or length? We also build to custom order.

100+

Regions

99.9%

Uptime

25,000+

Clients

24/7

Support

Request a Fiber Cable Quote

Send the fiber count, type and footage. We reply with a spec, price and lead time.

Prefer email? Write to kevin@vocom.com and the same team replies.

Data center fiber cabling with MPO trunk cassettes (illustrative render)Illustrative render

What a trunk cable is

A fiber optic trunk cable is a factory-terminated, multi-fiber assembly that carries many fibers between two distribution points, such as the main and horizontal distribution areas of a data center. Because it is terminated and tested at the factory, nothing has to be spliced on site. At the rack end it breaks out to duplex LC through a cassette or a harness, and the last hop into the switch is the transceiver.

Fiber counts

8F to 144F as MTP trunk (MTP-TRUNK-8 to MTP-TRUNK-144), 12F to 864F as MPO trunk

Fiber type

OS2 single-mode, OM3 and OM4 multimode

Polarity

Type A, B or C, built to your patching scheme

Construction

Double-jacketed backbone cable, factory terminated and tested, pulling eye option

Rating

OFNP plenum available, plenum and riser rated, low smoke zero halogen

Breakout

LC cassettes (12F to 24F) or MPO to LC harness (8F to 24F)

Panel density

144F per 1U, as twelve modular cassettes

Lead time

6 to 8 weeks from PO, 2 to 3 weeks by air, up to 10 weeks for custom builds

Trunk counts by zone

Trunk counts are sized to the zone they serve: lower counts for horizontal and equipment runs, high counts on the backbone between rooms. Specified per run and supplied to order.

8F

12F

24F

48F

96F

144F

288F

576F

864F

Trunk, breakout and patching products

Why source it through Vocom

Build-to-order: specified to your route, count and jacket, not off a fixed shelf.

Fujikura preform glass: tier 1 manufacturing, consistent quality.

Lead times that move: supply when domestic loose-tube is quoted months out.

Import/export handled: documentation, customs and delivery coordinated.

Founded in 1993: a supplier that also runs networks.

MTP trunk cable FAQ

What is an MTP trunk cable?

An MTP trunk cable is a factory-terminated, multi-fiber fiber optic trunk with MTP connectors, used to carry many fibers between distribution points in a data center. Vocom supplies them from 8F to 144F as MTP trunk and up to 864F as MPO trunk, built to order in 6 to 8 weeks.

What is the difference between MPO and MTP?

MPO is the multi-fiber connector standard. MTP is one manufacturer's version, built to tighter tolerances and intermateable with standard MPO. Every MTP is an MPO. Not every MPO is an MTP.

Which polarity should I order?

Type A, B and C are all available, specified per order. Tell us the polarity method your patching scheme uses and the trunks are built to match.

What fiber counts do trunk cables come in?

8F to 144F as MTP trunk under codes MTP-TRUNK-8 to MTP-TRUNK-144, and 12F to 864F as MPO trunk for the backbone between rooms. For other counts, send the spec and we will quote it as a custom build.

Single-mode or multimode trunk?

OS2 single-mode for distance, OM3 and OM4 multimode for short reach inside a row. The deciding factor is the link budget on the longest run in the zone.

Does the trunk depend on my switch brand?

No. It depends on the transceiver at each end. A 40G or 100G SR4 module uses 8 of the 12 fibers in an MPO, so two switches from different vendors running the same optics take the same trunk.

How does a trunk connect to equipment?

Through an LC cassette in a 1U panel, or a harness that breaks the MPO out to duplex LC. See modular cassettes and harness breakouts.

What is the lead time for MTP trunk cable?

6 to 8 weeks from PO, 2 to 3 weeks expedited by air, and up to 10 weeks for custom builds. Large orders can be staged to your build phases.

What should I put on the order?

Fiber count, fiber type (OS2, OM3 or OM4), polarity, length, jacket rating, whether you need a pulling eye, quantity and needed-by date.

Need Trunks for a Specific Build?

Send the counts, lengths, fiber type and polarity per zone. We will confirm the full spec, price and lead time against your build.

Talk to a Specifier