Outdoor fiber cable supply

Data Center Fiber Cabling, From Meet-Me Room to Rack

Data Center Fiber Cabling, From Meet-Me Room to Rack

Data Center Fiber Cabling, From Meet-Me Room to Rack

Factory-terminated MPO and MTP trunks, cassettes, adapters and indoor rollable ribbon to 864F. Sourced build-to-order from tier 1 manufacturers, staged to your build phases and delivered in 6 to 10 weeks from PO.

Factory-terminated MPO and MTP trunks, cassettes, adapters and indoor rollable ribbon to 864F. Sourced build-to-order from tier 1 manufacturers, staged to your build phases and delivered in 6 to 10 weeks from PO.

Factory-terminated MPO and MTP trunks, cassettes, adapters and indoor rollable ribbon to 864F. Sourced build-to-order from tier 1 manufacturers, staged to your build phases and delivered in 6 to 10 weeks from PO.

Build-to-order outdoor cable

MPO and MTP

144F to 864F

OS2, OM3, OM4

Factory terminated

100+ regions

99.9% uptime

25,000+ clients

24/7 support

What it is

What it is

Everything between the street and the final rack hop is passive. Outside plant cable arrives, gets spliced in the meet-me room from outdoor jacket to plenum or riser rated, and runs as factory-terminated trunk through the main, horizontal and equipment distribution areas. Only at the last hop does an active transceiver appear. Get the passive layer wrong and no transceiver fixes it.

Product codes

MPO and MTP trunk, LC and SC patch, cassettes and adapters, rollable ribbon ISP

Fiber type

OS2 single-mode, OM3 and OM4 multimode

Fiber counts

12F to 864F, 144F per 1U

Construction

Factory terminated trunk, harness breakout, modular cassette

Jacket and protection

Plenum and riser rated, armored optional, low smoke zero halogen

Deployment

MMR, MDA, HDA, EDA, rack

Lead time

6 to 10 weeks from PO, staged delivery available

Trunk counts and panel density

Trunk counts and panel density

Trunk counts sized to the zone they serve, terminated at the factory so nothing gets spliced on site that does not have to be.

12F

24F

48F

96F

144F

288F

576F

864F

Why source it through VOCOM

Why source it through VOCOM

Build-to-order — specified to your route, count and jacket, not off a fixed shelf.

Fujikura preform glass — tier 1 manufacturing, consistent quality.

Lead times that move — supply when domestic loose-tube is quoted months out.

Import/export handled — documentation, customs and delivery coordinated.

27 years in telecommunications — a supplier that also runs networks.

Data center fiber cabling FAQ

Data center fiber cabling FAQ

OS2 or OM4, which should we specify?

OS2 single-mode for distance, OM3 and OM4 multimode for short reach inside a row. The deciding factor is the link budget on the longest run in the zone, not what the last build used.

How much fiber fits in 1U?

144F in a fixed 1U unit, built as twelve modular cassettes. An 864F rollable ribbon trunk feeds a stack of them.

Which MPO polarity do you supply?

Type A, B and C are all available, specified per order. Tell us the polarity method your patching scheme uses and the trunks are built to match.

Can delivery be staged to our build phases?

Yes. Large orders are commonly split across phases so cable is not sitting on site months before the racks land. Lead time is 6 to 10 weeks from PO on the first tranche.

Building out a hall this year?